Profoto 1200 Work Light User Manual


 
18
One head
1. Connect the head to socket A.
2. Reduce the energy one f-stop by switching A+B / A<- >B
switch to position A<- >B.
3. Further reduce the energy one or two f-stops by halving or
quartering the energy with the A-switch.
4. Use the dial BRACKET for fine adjustments and to further
reduce the energy by two f-stops.
Two heads
Symmetrical light distribution
1. Connect the two heads to the B sockets.
2. Reduce the energy one f-stop by switching A+B / A< -> B
switch to position A<- >B.
3. Further reduce the energy one or two f-stops by halving or
quartering the energy with the B-switch.
4. Use the dial BRACKET for fine adjustments and to further
reduce the energy by two f-stops.
Asymmetrical light distribution
1. Connect one head to the A socket and one head to one
of the
B sockets.
2. Set the A+B / A <-> B switch in position A<->B.
The energy for the two heads is now individually controlled.
3. Reduce the energy one or two f-stops by halving or quarte-
ring the energy with the A-switch for the head connected to
the A-socket.
Energy distribution