Energy distribution Acute2 twin
One generator
1. Connect the head sockets to the two B sockets on the
generator.
2. Reduce the energy one f-stop by switching A+B / A<->B
switch to position A<->B.
3. Further reduce the energy one or two f-stops by halving or
quartering the energy with the B-switch.
4. Use the dial BRACKET for fine adjustments and to further
reduce the energy by two f-stops.
Two generators
1. Connect the head socket to socket A on each generator.
2. Reduce the energy one f-stop by switching A+B / A<-> B
switch to position A< -> B on both generators.
3. Further reduce the energy one or two f-stops by halving or
quartering the energy with the A-switch on both generators.
4. Use the dial BRACKET for fine adjustments and to further
reduce the energy by two f-stops on both generators.