26
Troubleshooting Guide
Technical data
Recycling time, sec
Mains voltage Acute2 1200 Acute2 2400
240V 50 Hz 0.09-1.6 s 0.18-3.2 s
100V 50 Hz 0.12-2.7 s 0.24-5.1 s
117V 60 Hz 0.09-1.5 s 0.17-2.9 s
Duration and recycling data are approximate and may differ slightly between units due
to component variations
Size (height x length x width)
2400Ws 13x19x30cm (5.1x7.5x11.8in) incl. Handle
1200Ws 13x19x22cm (5.1x7.5x8.7in) incl. Handle
Weight
2400Ws 5.9kg (12.9 lb)
1200Ws 4.1kg (9.0 lb)
Max Modelling lamp
500W and 1000W per generator
Problem
• No ready lamp but ready sound
• No flash
• Fuses keep blowing
• Continuous red light in Photocell
• Generator works badly or shuts
off after a few seconds
• Slow recharging /recycling
• Flashing red light in Photocell
• Bad mains quality?
Action
• Change ready lamp
• Check flash tube
• Reduce recycling speed
• Generator is overheated
• Check voltage settings on
generator.
• Low mains voltage? - Reduce the
BRACKET(15)
• Indicates slow recycling setting
• Check setting of recycling time