n Know your power tool. Read operator’s manual care-
fully. Learn its applications and limitations, as well as the
specific potential hazards related to this tool. Following
this rule will reduce the risk of electric shock, fire, or seri-
ous injury.
n Drain tank of moisture after each day’s use.
If unit will not be used for a while, it is best to leave drain
valve open until such time as it is to be used. This will
allow moisture to completely drain out and help prevent
corrosion on the inside of tank.
n Risk of Fire or Explosion. Do not spray flammable liquid
in a confined area. Spray area must be well ventilated. Do
not smoke while spraying or spray where spark or flame
is present. Keep compressors as far from the spraying
area as possible, at least 15 feet from the spraying area
and all explosive vapors.
n Risk of Bursting. Do not adjust regulator to result in
output pressure greater than marked maximum pressure
of attachment. Do not use at pressure greater than 135
PSI.
n If connected to a circuit protected by fuses, use time-
delay fuses with this product.
n To reduce the risk of electric shock, do not expose to
rain. Store indoors.
n Inspect tank yearly for rust, pin holes, or other im-
perfections that could cause it to become unsafe.
Never weld or drill holes in the air tank.
n Make sure the hose is free of obstructions or snags.
Entangled or snarled hoses can cause loss of balance or
footing and may become damaged.
n Use the air compressor only for its intended use. Do
not alter or modify the unit from the original design
or function.
n �Always be aware that misuse and improper handling
of this tool can cause injury to yourself and others.
n �Never leave a tool unattended with the air hose at-
tached.
n �Do not operate this tool if it does not contain a legible
warning label.
n �Do not continue to use a tool or hose that leaks air or
does not function properly.
n Always disconnect the air supply and power supply
before making adjustments, servicing a tool, or when a
tool is not in use.
n Do not attempt to pull or carry the air compressor by
the hose.
SERVICE
n Tool service must be performed only by qualified re-
pair personnel. Service or maintenance performed by
unqualified personnel may result in a risk of injury.
n Disconnect power supply, open drain valve to de-
compress tank and allow water to drain, and allow
air compressor to become cool to the touch before
GENERAL SAFETY RULES
servicing. Turn pressure regulator knob fully clockwise
after shutting off compressor.
n When servicing a tool, use only identical replacement
parts. Follow instructions in the Maintenance sec-
tion of this manual. Use of unauthorized parts or failure
to follow Maintenance instructions may create a risk of
injury.
SPECIFIC SAFETY RULES
n Your tool may require more air consumption than this
air compressor is capable of providing.
n �Always follow all safety rules recommended by the
manufacturer of your air tool, in addition to all safety
rules for the air compressor. Following this rule will
reduce the risk of serious personal injury.
n �Never direct a jet of compressed air toward people or
animals. Take care not to blow dust and dirt towards
yourself or others. Following this rule will reduce the risk
of serious injury.
n Do not use this air compressor to spray chemicals.
Your lungs can be damaged by inhaling toxic fumes. A
respirator may be necessary in dusty environments or
when spraying paint. Do not carry whilte painting.
n Inspect tool cords and hoses periodically and, if dam-
aged, have repaired at your nearest Authorized Ser-
vice Center. Constantly stay aware of cord location.
Following this rule will reduce the risk of electric shock
or fire.
n �Never use an electrical adaptor with this grounded
plug.
n Check damaged parts. Before further use of the air
compressor or air tool, a guard or other part that is
damaged should be carefully checked to determine
that it will operate properly and perform its intended
function. Check for alignment of moving parts, bind-
ing of moving parts, breakage of parts, mounting, and
any other conditions that may affect its operation. A
guard or other part that is damaged should be properly
repaired or replaced by an authorized service center.
Following this rule will reduce the risk of shock, fire, or
serious injury.
n Make sure your extension cord is in good condition.
When using an extension cord, be sure to use one
heavy enough to carry the current your product will
draw. A wire gauge size (A.W.G.) of at least 14 is rec-
ommended for an extension cord 25 feet or less in
length. A cord exceeding 50 feet is not recommended.
If in doubt, use the next heavier gauge. The smaller
the gauge number, the heavier the cord. An undersized
cord will cause a drop in line voltage resulting in loss of
power and overheating.
n Save these instructions. Refer to them frequently and
use them to instruct others who may use this air com-
pressor. If you loan someone this tool, loan them these
instructions also.