Schumacher 85-716 Battery Charger User Manual


 
10
10.5 CAUTION - Do not leave Manual chargers unattended.
10.6 CAUTION: If at any time the battery gets hot (above 125°F (52°C)) or acid
comes out of vent caps, STOP charging.
10.7 To maximize battery life - Let automatic chargers complete charging.
11. MULTIPLE BATTERY CHARGING
Batteries of the same voltage may be connected in parallel for
maintenance charging. Charge time increases in proportion to the number
of batteries. Rate of charge decreases in the same proportion.
Example: Charging 2 batteries in parallel will take 2 times longer; each
battery receives 1/2 the amount of charge showing on the ammeter. Thus,
if the ammeter shows a 30-amp charge, each battery will get a 15-amp
charge (when batteries have the same rating, same state of charge, etc.).
12. CHARGER FEATURES AND CONTROLS
12.1 LED Indicators: The battery charger has three LED lights. They indicate
different functions.
RED LED - A steady glow indicates POWER ON. Red LED ashes if there
is a problem (i.e. battery isn't charged within 8 hours).
YELLOW LED - A steady glow indicates proper connection to the battery.
Flashing yellow indicates no connection or reverse connection.
GREEN LED - A steady glow indicates that Float-mode Monitoring is
keeping your battery maintained at full charge.
As a safety precaution, after 24-hours of charging, the charger
automatically switchs OFF.