Installation Instructions (continued)
Step :3
Convert The Oven Burner Orifice
For LP Gas
Oven Burner:
1. Remove oven door, kick panel, oven bottom and
burner baffle, The burner orifice spud is located
behind a metal shield at the center bottom of range°
2. Remove metal shield and use a 1/2" wrench to turn
the burner orifice spud clockwise° Tighten spud only
"until it is snug with the base. To prevent leakage, do
not overtighten spud or loosen spud after it is snug.
Step 4
Adjusting The Air Adjustment Shutters
For LP Gas
For location of and access to air adjustment shutters,
see page 8..
Loosen the Phillips head
screw and rotate the shutter
to the full open position. With
baffle in place, flames should
have approximately 1-inch ___._ .t
blue cones and should not screw--_
extend beyond the edges of
) t._==
the burner baffle. For LP
gas, this should occur when
the air adjustment shutter is
completely open,, After 30
seconds of burner operation, check for flames lifting
off burner ports. If lifting is observed, gradually reduce
air shutter opening until flames are stabilized.
Broil Burner:
Use a 1/2" wrench to turn the upper burner orifice
spud clockwise. Tighten spud only until it is snug with
the base. To prevent leakage, do not overtighten spud
or loosen spud after it is snug.
I2