Using the charger
12
̈ Place the receiver into any charging compartment. The LED ¹ on the
receiver indicates the charge status.
Charging a completely discharged rechargeable battery takes approx.
3.5 hours at room temperature. However, the charging process may take
longer if:
the rechargeable battery is deep discharged and first has to be recondi-
tioned by a deep discharge recovery charge,
the temperature of the built-in rechargeable battery is below 3°C or
over 40°C, since, in order to protect the rechargeable battery, the
charging process will be interrupted until the temperature is again
within the permissible range and the LED ¹ lights up,
the additional temperature protection of the charger interrupts the
charging process until the charger has cooled down.
Setting the receiver channel(s) using the channel copy function
You can simultaneously set all receivers in the charger to the same
channel. The channel copy function allows you to copy the current channel
of the receiver placed into the “master” charging compartment · to all
other receivers in the charger.
̈ Place all receivers which are to be set to the same channel into the
“slave” charging compartments ³ (light blue in the diagram).
̈ Place the receiver whose channel you want to copy into the “master”
charging compartment ·.
The LED
COPY AVAILABLE
»
lights up green as long as the channel
copy function is available (see: LED indication for “automatic copying”
function on page 6).
Tip:
If you do not press the COPY button ¿ within 2 minutes, the LED
COPY
AVAILABLE
»
goes off and the “automatic copying” function is no
longer available. To reactivate this function, remove the receiver from
the “master” charging compartment · and place it back again.
̈ Press the COPY button ¿ to start the channel copy function.
The LC displays Ƹ of all receivers which are successfully set to the same
channel light up.
¹¹
LED ¹ Meaning
lights up red The built-in rechargeable battery is being charged.
lights up green The built-in rechargeable battery is fully charged.
flashes red The temperature of the built-in rechargeable
battery is below 3°C or over 40°C. The charging
process will be interrupted until the temperature of
the built-in rechargeable battery is again between
3°C and 40°C.
lights up
orange
The built-in rechargeable battery is defective.
Interrupt the charging process and contact your
Sennheiser service partner.
·