Woodstock W1713 Saw User Manual


 
-13-
W1713 Owner's Manual (Mfg. Since 6/03)
SETUP
Dust Collection
We recommend that you connect the 1
1
4" dust port of
your scroll saw (see Figure 11) to a shop vacuum to keep
the wood debris from accumulating underneath the table
insert, which could interfere with blade movement.
Calibrating Table Tilt
Scale
The table lock knob and tilt scale are used to tilt the
table for horizontal angle cuts.
Note: The table tilt scale is only an approximate scale
and should not be used when precise angle measurements
are required for the operation.
Tools Needed Qty
Phillips Screwdriver #2 .........................................1
Wrench 10mm ...................................................1
To calibrate the table tilt scale, do these steps:
1. DISCONNECT MACHINE FROM POWER!
2. Loosen the jam nut on the table stop bolt shown in
Figure 10, then thread the stop bolt in so that it
will not interfere with the table adjustment.
3. Loosen the table lock knob (see Figure 11).
4. Place a small machinist's square up against the
blade, adjust the table tilt until the table is flat
against the bottom of the square, then re-tighten
the lock knob.
5. If necessary, use the Phillips head screw on the
pointer to adjust the pointer tip to the zero mark on
the scale.
6. Thread the table stop bolt up so that it just contacts
the bottom of the table, then secure it in place with
the jam nut.
Figure 11. Table tilt controls and scroll
saw dust port.
1
1
4" Dust Port
Lock Knob
Pointer
Figure 10. Table stop bolt.
Table
Stop Bolt