SET UP
14. Attach the outlet port and filter L-braces to the
housing with the outlet gasket between, as shown in
Figures 23 & 24 using the fasteners below.
—Model W1810: Use (10)
5
/16"-18 x 1" hex bolts, (20)
5
/16" flat washers, and (10)
5
/16"-18 hex nuts.
—Model W1809: Use (11)
5
/16"-18 x 1" hex bolts, (22)
5
/16" flat washers, and (11)
5
/16"-18 hex nuts.
—Model W1808: Use (8)
5
/16"-18 x 1" hex bolts, (16)
5
/16" flat washers, and (8)
5
/16"-18 hex nuts.
15. Model W1810 Only: Attach the filter cross braces to
the L-braces, as shown in
Figure 25, using (4)
3
/8"-16
x
3
/4" hex bolts, (8)
3
/8" flat washers, and (4)
3
/8"-16
hex nuts.
16. Using the forklift, lift the entire assembly approxi-
mately 2' off the ground to gain clearance for filter
installation.
Figure 23. Attaching the outlet port and
filter L-braces to the blower housing
(Model W1810).
Figure 24. Filter L-braces atttached to
blower housing (Model W1810).
Gasket
Figure 25. Filter cross braces (Model
W1810).
Cross Braces