Simrad SIMRAD HS50 Stud Sensor User Manual


 
INSTALLATION
20221081 / F 13
Pedestal mounting (option)
An optional mounting pedestal (part no. 20213021) can be
delivered from Simrad by request. This pedestal is designed for
2-inch mast mounting.
Attach the pedestal to the Sensor unit with the four screws and
washers similar to the bracket mounting option described on
page 12.
self-bonding tape
Connector with
Cable duct
Cable ties
Pipe clamps
1 Lift the Sensor unit in the preferred direction
on the mast. Use two pipe clamps with
preferred size for mounting the Sensor unit
pedestal to the mast top.
2 Ensure that the Sensor unit is mounted in
such a way that torsion movement relative to
the mast is kept at an absolute minimum.
All nuts should be secured with washers or by
self-locking nuts.
Connect the cable from the Processing unit to the cable as
described in page 11.
Cable wiring
The wiring for the Sensor unit cable in the Processing unit
terminals is as follows:
Cable Wire No. Signal Description
Processing Unit
Connector P201
Label
Screen Cable shield GND
4 Transmit COMM+
3 Receive COMM-
2 +24 VDC PWR+
1 Power ground PWR-