Simrad SIMRAD HS50 Stud Sensor User Manual


 
INSTALLATION
20221081 / F 27
Data output
The Processing unit has two individually configurable output
serial lines.
On output line Data output 1 two RS-232 and two 422 serial
lines are available. The signal cables can be connected to both
terminal block P202 and P203.
On Data output 2 one RS-232 and one 422 serial lines are
available. The signal cables are to be connected to terminal
block P204.
Note! All six serial lines may be used simultaneously!
The setup of baud rate, interval between NMEA sentences and
output formats for each port are performed in the Data output 1
and Data output 2 submenu.
Baudrate: The rate at which bits are transmitted. 4800 is
standard NMEA rate.
Interval: Interval in seconds between each NMEA
sentence.
Example:
Interval setting Hz
1 sec 1 Hz
0.5 sec 2 Hz
0.2 sec 5 Hz
0.1 sec 10 Hz
0.05 sec 20 Hz
Format: Format on data output line. The following
selections are available: NMEA and none.
NMEA Format: NMEA sentences to be sent to output line.
WARNING! If “none” is selected as output format, no data will be
sent to output line.