Stanley Black & Decker EP30 Nail Gun User Manual


 
12
TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
Brazing pin does not ignite
or does not ignite long
enough.
Batteries not charged or are defective.
Test batteries for proper charge. Replace and/or
charge as necessary.
Blown fuse. Check fuses.
Magnetic ground faulty.
Check that surface magnetic ground is applied to
is ground clean. Check magnetic ground cable
and plug for damage.
Faulty cables. Check gun cables and plugs for damage.
Bonding surface contaminated. Check that the brazing surface is ground clean.
Braze is faulty. Batteries not charged or are defective.
Test batteries for proper charge. Replace and/or
charge as necessary.
Incorrect PIN TYPE setting. Check PIN TYPE setting on the control box.
Magnetic ground faulty.
Check that surface magnetic ground is applied to
is ground clean. Check magnetic ground cable
and plug for damage.
Bonding surface contaminated. Check that the brazing surface is ground clean.
Incorrect grinding wheel is used. Use only Tyrolit grinding wheels or carbide burr.
Ceramic ring was not positioned
square to the lug.
Ensure ring is positioned correctly.
Brazing pin not positioned correctly in
lug hole.
Ensure pin is positioned correctly.