Sterling SSV-05R Air Compressor User Manual


 
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 14 of 36
2-4 Connecting the Compressed Air Supply
Before connecting the compressed air supply, check the following:
Check compressed air piping for correct installation and assembly.
Check the fittings, length and quality of the hose connections for
agreement with requirements.
Check all compressed air lines for leakages.
You need a compressed air supply with 70-90 psi (5-6 bar) system pressure.
The air should be free of oil and water.
1. Find the compressed air hose, which has
been supplied.
2. Connect it to the venturi assembly and to
the control and maintenance unit.
3. The compressed-air hose is firmly pressed
into each connecting socket.
4. Connect the control and maintenance unit
to the compressed air supply. Max. input
pressure 145 psi (10 bar) system pressure.
5. Set the pressure on the pressure reducer
at 70-90 psi (5-6 bar).
Maximum input pressure: 145 psi (10 bar) system
overpressure.
Maximum output pressure: 90 psi (6 bar).
Fi
g
ure 3: Venturi Assembl
y