Sterling SSV-05R Air Compressor User Manual


 
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 25 of 36
5-4 Troubleshooting
PROBLEM REMEDY (See Test Steps Below)
The unit is not conveying and is not
active.
A, B, G, H
The unit is not conveying; the
compressed air valve is switched
when the device is switched on.
C, F
The unit is not conveying; the
compressed air is flowing.
C, D, E, F, I, J, K
The unit is overfilled. G, L, M
The unit is not filled properly. C, D, E, F, I, J, K, L
Test steps:
Make sure the unit is switched ON.
Make sure the unit is plugged in and the proper voltage is present.
Make sure sufficient compressed air is available 70-90 psi (5-6 bar).
Make sure the venturi assembly is inserted in the material.
Make sure the compressed air hose is properly connected to the
venturi assembly.
Make sure the compressed air hose is properly connected to the
maintenance unit.
Make sure the level sensor is properly adjusted.
Make sure the cable of the level sensor is properly connected.
Make sure the filter to is not clogged.
Make sure the screen is not clogged.
Make sure the conveyor vinyl flexible hose is properly connected.
Make sure the compressed air supply is properly adjusted.