Sterling SSV-05R Air Compressor User Manual


 
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 24 of 36
Disassembly
1. Remove the filter cartridge (A).
2. Blow out the filter cartridge (A) from the inside out using compressed air or
replace the filter.
3. Open the toggle-type fastener (B) and fold the hopper lid upward (C).
4. Check the screen (D) within the lid for material residue. (If you are
disassembling the screen for cleaning, draw the screen out of the fit of the
gasket ring).
5. Clean the screen (D) using compressed air.
6. Replace the screen and gasket ring as needed if damage you detect
damage.
Assembly
1. Assemble the screen and the gasket ring.
2. Check the screen for proper fit.
3. Clean the hopper loader using a vacuum cleaner.
4. Close the hopper lid.
5. Close the toggle-type fastener.
6. Assemble the filter cartridge.
5-3 Adjusting the Level Probe
See Chapter 4: Setup.
Order number level probe: ID 85480