-12-
E.3 LED INDICATOR:
LED Name L ED ON LED Blink LED OFF
1
AC IN 1. Input voltage normal, and
position transfer
Voltage Level”
(150VAC~240VAC)
2. Input voltage frequency
range in between(45~60Hz)
Has input power, but
voltage or frequency is not
in the allowance range.
No input power
2
CHARGER Green : Battery charger is
working.
Green Blink : Battery
charger is standby.
Orange Blink : Battery
charger is disable.
--------------
3
SOLAR PANEL Solar module is delivering
energy.
-----------------------------
1. Solar module
aren’t connect
or
2. Day or Night /
(cloudy day)
4
SOLAR
CHARGER
Solar charger is working.
------------------------------
Solar charger is
disabled.
5
AC OUT There is voltage at the “AC OUT”
terminal.
No voltage at the “AC
OUT” terminal.
-------------
6
INVERTER Green : Inverter is working. Green Blink : Inverter is
standby
Orange Blink : Inverter is
disable.
--------------
7
EQUALIZE In Equalize charging
Process
------------------------------
Disable Equalize
charging function
8
BATTERY Approx state of charge or discharge of Battery.
9
BYPASS Green : BYPASS switch is active
AC IN voltage is being sent
directly to AC OUT terminal
Green Blink :BYPASS
switch standby.
Orange Blink : BYPASS
switch disable
---------------
10
RUN/STOP Green : Invertek turn on.
Red : Invertek turn off.
Red Blink : Auto-Restart
is in use
---------------