Sterling Power Products DAI-1500C-12xx Battery Charger User Manual


 
Fn00 Fn01 Fn02 Fn03 Fn04 Fn05 Fn06 Fn07 Fn08 Fno9
DSPL FUNC
ENT
AUX
Battery type
0= Open lead acid
1= Gel ( exide ) setting
2= Gel u.s.a setting
3= Agm sealed
inverter voltage
0) 200 v 50 hz
1) 220 v 50 hz
3) 240 v 50 hz
2) 230 v 50 hz
power saver mode
1) power saver on
2) power saver off
system fuctions
0) all functions normal
1) inverter off, charger and bypass on
2)charger and bypass off, inverter on
3) inverter and charger off, bypass on
aux 1 setup
0) on when charger on
1) on when charger off
2) on when inverter on
3) on when inverter off
aux 2 setup
0) on when charger on
1) on when charger off
2) on when inverter on
3) on when inverter off
input current limit setup
0) 25 % power 4 amps
1) 50% power 7 amps
2) 75% power 11 amps
3) 100% power 15 amps
charging current reduction
0) 25% reduction
1) 50% reduction
2) 75% reduction
3) full current
solor charger
1) on
2) off
low voltage cut out
0) 10.0 v
1) 10.5 v
2) 11.0 v
3) 11.5 v
4) 12.0 v
System Adjustments
To adjust any of the unit’s preset parameters ) the unit must be in STOP mode! Select the
function you wish to change from the list of light blue boxes below. Select the parameter in the box you wish to change. For example, if you wish to switch the power saver
function off, you find that the power saver function is attached to (function 2) and that selection means “off”. To select this desired option go to the main key pad on the
front of the unit. Push the pad marked FUNC (function) for 2 seconds and use up/down keys to scroll through the functions. (The display will show up to ) Stop at
the function you require. (For power saver stop at .) With on the screen push ENT on the keypad and use the up/down arrows to select the parameter
required. The display will show from to (depending on which parameter you wish to change). Then select the parameter number you wish (in this case the power saver
off function which is ), by using the up/down keys and push the ENT key to enter that selection. After the selection has been made the display will show and this will
complete the parameter change. Then press DSPL to return to the function heading (one level upwards). Either continue to next function or press DSPL again to
return to the voltage display mode. The unit will also automatically return to the voltage display after about 20 seconds if left alone. Don’t forget to return to RUN mode!
(factory settings are highlighted in dark blue in each function box/default
Fn02 2
Fn00 Fn09.
Fn02 Fn02
00 06
2 End
(”enter”)
adjusting the
screen example Fn09