Sterling Power Products PS1212 Battery Charger User Manual


 
Sterling Power Management Panel
The Sterling Power Management Panel is the perfect complimentary product for your ProSport battery
charger. It measures voltages and amps independently at up to four different measuring points and, for
example, keeps you informed about the charge current and the charge voltage. Moreover, it includes an amp
hour counter to indicate how many amp hours you have used or recharged. Contact your local Sterling dealer
for further details on this product.
Important Notice: FCC Class A Part 15 Notification
Your Sterling ProSport battery charger has been designed and tested to comply with FCC Class A part 15.
These regulations are to provide adequate protection agaings harmful interference while operated in a
commercial application. If in a residential setting you are encountering interference with TV and radio
reception, simply remove AC from the ProSport to confirm if your battery charger is causing interference. As
an end user you can explore the following measures to minimise interference.
1) Choose a different AC circuit to power your ProSport charger.
2) Make sure all electrical appliances are properly grounded.
3) Re-position receiving aerial.
12 13
Trouble Shooting Guide
No Red or Green LED Indicator
Check for loss of power at the AC outlet. Confirm RCD has not tripped. Check with a meter or AC test
light that AC is present at the end of your extension cord.
Confirm all charger cables are installed with the correct polarity connections at each battery and that all
connections are clean and tight.
With the AC power removed and the engine switched off, check the charge level of each battery with a
DC meter or with the Sterling DC Voltage Probe & Diagnostics Tool. If there is no charge level indication
for a battery, check each battery with a hydrometer to determine if it has one or more bad cells.
(Batteries should always be replaced in sets and always the same type.)
If everything above checks out okay and you still don’t get any output from the charger, contact Sterling
Power Products for product service.
Battery is Not Charging, Red and Green Indicator is “on”
Confirm all charger cables are installed with the correct polarity connections at each battery, and that all
connections are clean and tight. Reverse polarity connections will blow output fuse, resulting in no
output voltage.
With the charger on, read DC voltage at each battery. If any of the readings are less than 13 volts,
proceed with the following:
A. Disconnect AC power at the AC outlet.
B. Remove charger cables from each battery.
C. Reconnect AC power and read DC voltage across each output cable. If output voltage is
approximately 13 volts, then the charger is okay and each battery should be tested with a hydrometer
with the charger and the engine off to determine if one or more batteries have bad cells. (Batteries
should always be replaced in sets and always the same type.)
D. If there is no output when trying to read DC voltage, check each output fuse and replace as needed.
If the DC voltage at each charger output is less than 13.0 volts, contact Sterling Power Products for
product service.
4) Make sure that all AC, DC and aerial cables are well apart from each other. Use shielded cables or special,
separate shielding devices.
5) Relocate charger so that it is at the furthest point from home receiving equipment (TV, radio etc.).
Important Notice: FCC Class A Part 15 Notification Continued
Specifications
ProSport8 12/24 8A max. max. 2 184 x 64 x178 3,6kg 180V - 264V AC
Model Voltage Amps battery banks Size W x H x D (mm) Weight AC Input Voltage
ProSport12 12/24 12A max. max. 2 184 x 64 x216 4,1kg 180V - 264V AC
ProSport20 12/24 20A max. max. 2 184 x 64 x273 4,5kg 180V - 264V AC
ProSport20plus 12/24/36 20A max. max. 3 184 x 64 x273 5,0kg 180V - 264V AC
ProSport20plus-110 12/24/36 20A max. max. 3 184 x 64 x273 5,0kg 90V - 135V AC
ProSport20-110 12/24 20A max. max. 2 184 x 64 x273 4,5kg 90V - 135V AC
.
Artikel
DC Voltage Probe & Diagnostics Tool for 12V Systems
DC Voltage Probe & Diagnostics Tool for 24V Systems
Clamp-on DC/AC Amp & Volt Meter
Power Management Panel with Amp Hour Counter
200A Shunt for Power Management Panel
.
Optional Accessories
TM12V
TM24V
Artikel-Nr.
TM12V
TM24V
CLAMP1
CLAMP1
lightlight
CE
on/offon/off
beepbeep
1
2
3
4
2
4
3
1
Power Management
with
AMP Hr Counter
Sterling Power ProductsSterling Power Products
Amp
hr
Amps VoltsAmps Volts
14.35 v m Pos 4
35.7A -435 Ah
on/off
alarm
light
PMP1
PMP1
S200A
S200A
To place an order please contact
your local Sterling dealer. A
dealer directory can be found on
www.sterling.power.com.