Studer Innotec HPC 2800-12, HPC 4400-24, HPC 600-48, HPC 6000-48 Battery Charger User Manual


 
STUDER INNOTEC HP-COMPACT
HP-COMPACT V5.4 13/80
including the battery. If after the fuse replacement and after re-connection of the
battery with the right polarity, the HP-COMPACT remains out of order, it must be
brought back to your merchant for service.
3.6.2 Connection to the 230Vac-consumer appliances (AC OUTPUT)
The 230V consumer appliances must be connected to the terminals AC OUTPUT
with cables which cross section has to follow the local rules in force (usually
2.5mm2). Connections are marked as follows “N“ Neutral, “PE“ Earth (connected to
the appliance box), “L“ Live.
Caution: High voltages can be there. Make sure that the HP-COMPACT is
turned off (LED 13 lighting) before the connection.
3.6.3 Connection to the 230Vac Input (AC INPUT)
The 230V-supply from network or from a generator must be connected to the input
terminals AC INPUT with cables which cross section depends on the power source
(usually 2.5mm2). Connections are marked as follows: “N“ Neutral, “PE“ Earth, “L“
Live (connected to the appliance case).
3.6.4 Connection to Auxiliary Contact
This contact is a potential free change over contact the currents and voltages allowed
for this contact are max. 16A/250Vac. The LED 5 “Contact active” shows the position
of them: alight mind active and off mind non-active. The schematic view of the
connections on the front, show the relay in the non-active mode.
3.6.5 Connection to Remote control
The Remote Control RCC-01 is connected in the terminal marked „Remote control“
with a 20m long cable and a RJ11/8 connector. The Remote Control can be plugged
IN or plugged OUT during any operation situation. Push in the connector softly until
you hear the „click“ showing that the connector is locked. The same applies to the
plug in the Remote Control.
The length of the cable for Remote Control should not exceed 40m. We deliver it with
20m cable.
3.6.6 Connection to Temperature Sensor (Temp.)
The temperature sensor CT-35 is connected in the terminal marked „Temp“ with a
3m long cable and a RJ11/6 connector. The temperature sensor can be plugged IN
or plugged OUT during any operating situation. Push in the connector softly until you
hear the „click“ showing that the connector is locked. The temperature sensor must
be glued to the wall of the battery or near it. The Temperature Sensor cable must
not be tied together with the battery cables or laid in a rope/bundle.
3.6.7 Connection to the Remote Control for the „Power Sharing“ (RPS-01)
This remote control is connected with a 20m long cable and a RJ11/6 connector in
the connection terminal „F“ (Temp. sensor). It can be connected and disconnected at
any time. Push in the connector softly until you hear the „click“ showing that the
connector is locked. In case the remote control is connected together with the Temp.
sensor, a short cable with a Y-connector will be connected in the terminal „F“ (can be
supply as an option).