Universal Laser Systems X2-600 Engraver User Manual


 
8-2 Troubleshooting
Raster engraving appears sharp on
both ends of the engraving but fuzzy
in the middle
Dirty laser system
Something is loose
System needs tuning
Worn X-axis belt and/or drive gear
Tickle setting too low
Faulty laser tube
Clean all optics, rails, bearings and belts
Check X-axis bearings, drive gear, idler
pulley, belt, and optics
Run “Tuning” feature in printer driver version
4.17 and higher
Replace belt and/or drive gear, and run
“Tuning” feature
Adjust setting higher and recheck
Replace laser tube
Engraving does not appear as deep
as it normally does
Graphic, graphic software, graphic software
setup, color palette, monitor display colors, or
driver settings have changed
Out of focus
Material or material density has changed
Settings have changed
Dirty laser system
Laser tube cooling fan filters are dirty
Chiller not maintaining temperature(water
cooled versions only)
Ambient temperature not within specifications
Laser beam out of alignment with the optics
Air Assist cone misaligned (air assisted
versions only)
Faulty laser tube
Check to see what has changed. Use
“Software Setup Guide” to properly setup the
graphics software to work correctly with the
laser system. Check driver settings.
Re-focus
Check material
Check power, speed, PPI, and DPI settings
Clean all optics, rails, bearings and belts
Check and/or clean
Check, clean, or adjust chiller
Adjust ambient temperature to within
specifications
Check and/or adjust laser beam alignment
Check and/or adjust cone so that laser beam
is in center
Replace laser tube
Engraving is sharp, clear and at a
good depth on one side of the table
and fuzzy and shallow on the
opposite side of the table
Out of focus
Dirty laser system
Material is not level or varying in thickness
Table is not level
Laser beam out of alignment with the optics
Air Assist cone misaligned (air assisted
versions only)
Faulty laser tube
Re-focus
Clean all optics, rails, bearings and belts
Check focus point of material and different
places, adjust height by shimming material or
using more thickness-consistent material
Using the focus tool, focus directly on the
surface of the table in all four corners. Table
should be within +/- .020 inches from one
corner to the other. Adjust if necessary.
Check and/or adjust laser beam alignment
Check and/or adjust cone so that laser beam
is in center
Replace laser tube