Wagner SprayTech 110v Paint Sprayer User Manual


 
13
Super Finish 23 PLUS
GB
DISPLAYS AT THE UNIT / CLEANING THE UNIT
8 CLEANING THE UNIT
A clean state is the best method of ensuring operation with-
out problems. After you have nished spraying, clean the unit.
Under no circumstances may coating material rests dry and
harden in the unit. The cleaning agent used for cleaning (only
with a ash point above 21 °C) must be suitable for the coat-
ing material used.
Secure the spray gun, refer to the operating manual of
the spray gun.
Remove and clean the tip.
Unit with suction system
1. Set multifunction switch to (ON - circulation).
2. Remove suction tube from the material container, the re-
turn tube remains over the material container.
3. Immerse the suction system into a container lled with a
suitable cleaning agent
4. Turn the pressure control valve back in order to set a mini-
mal spraying pressure.
5. Set multifunction switch to (spray).
6. Pull the trigger guard of the spray gun in order to pump
the remaining coating material from the suction hose,
high-pressure hose and the spray gun into an open con-
tainer (if appropriate, increase the pressure at the pressure
control valve slowly in order to obtain a higher material
ow).
The container must be earthed in case of
coating materials which contain solvents.
Caution! Do not pump or spray in container
with small opening (bunghole)!
See safety regulations.
7. Set multifunction switch to (ON - circulation).
8. Pump suitable cleaning agent in the circuit for several
minutes.
The cleaning eect is increased by alterna-
tively opening and closing the spray gun.
9. Set multifunction switch to (spray).
10. Pump the remaining cleaning agent into an open contain-
er until the pump is empty.
11. Switch o the unit
Warm water improves the cleaning eect in
the case of water-dilutable coating materials.
Unit with upper hopper
1. Set multifunction switch to (ON - circulation).
2. Turn the pressure control valve back in order to set a mini-
mal spraying pressure.
3. Set multifunction switch to (spray).
4. Pull the trigger guard of the spray gun in order to pump
the remaining coating material from the hopper, high-
pressure hose and the spray gun into an open container (if
appropriate, increase the pressure at the pressure control
valve slowly in order to obtain a higher material ow).
The container must be earthed in case of
coating materials which contain solvents.
Caution! Do not pump or spray in container
with small opening (bunghole)!
See safety regulations.
5. Fill up hopper with suitable cleaning agent.
6. Set multifunction switch to (ON - circulation).
7. Pump suitable cleaning agent in the circuit for several
minutes.
with cleaning ring (TopClean) step 8 up to 12
8. Switch reverser knob into a horizontal position.
The cleaning agent will ow around the circumference of
the inner hopper wall and will clean it in some minutes,
depending of the fouling
9. Switch reverser knob into the upright position.
Cleaning agent is owing directly into the hopper
Do not switch the reverser knob at the clean-
ing ring into the horizontal position when
the pump is loaded with coating material.
The holes could be plugged.
As a result the cleaning function will be re-
duced, as the cleaning ring has to clean itself
rst.
10. Set multifunction switch to (spray).
11. Pump the remaining cleaning agent from the hopper,
high-pressure hose and the spray gun into an open con-
tainer
12. Set multifunction switch to (ON - circulation).
13. Switch o unit