12 ProSpray 3.23
GB
Cleaningtheunit(shuttingdown)
8.2 Suction lter
i
A clean suction lter always guarantees
maximum feed quantity, constant spraying
pressure and problem-free functioning of the
unit.
1. Screwoffthelter(Fig.7)fromsuctionpipe.
2. Cleanorreplacethelter.
Carry out cleaning with a hard brush and an appropriate cleaning
agent.
8.3 Cleaning the high-pressure lter
Cleantheltercartridgeregularly.
Asoiledorcloggedhigh-pressureltercancauseapoorspray
pattern or a clogged tip.
1. Turn the pressure control knob counterclockwise to
minimum pressure.
2. Open the relief valve, valve position PRIME
(kcirculation).
3. Switch the unit OFF.
Unplug the power plug from the outlet.
4. Unscrewthelterhousing(Fig.8,Item1).withastrap
wrench.
5. Pulltheltercartridge(2)fromthebearingspring(3).
6. Clean all the parts with the corresponding cleaning agent.
Ifnecessary,replacetheltercartridge.
7. ChecktheO-ring(4),replaceitifnecessary.
8. Placethebearingring(5)againstthebearingspring(3).
Slidetheltercartridge(2)overthebearingspring.
9. Screwinlterhousing(1)andtightenitasfaraspossible
with the strap wrench.
1
4
3
2
5
8.4 Cleaning Airless spray gun
1. Rinse Airless spray gun with an appropriate cleaning
agent.
2. Clean tip thoroughly with appropriate cleaning agent so
that no coating material residue remains.
3. Thoroughly clean the outside of the Airless spray gun.
Intake lter in Airless spray gun
Disassembly (Fig. 9)
1. Pullprotectiveguard(1)forwardvigorously.
2. Screwgrip(2)outofthegunhousing.Removeintakelter
(3).
3. Intakeltercongestedordefective–replace.
Assembly
1. Placeintakelter(3)withthelongconeintothegun
housing.
2. Screwingrip(2)intothegunhousingandtighten.
3. Slotinprotectiveguard(1).
W
arning:
keep clear
of tip
250 bar
m
ax.3600 psi
3
2
1
Uncontrolled Copy