Setup
3. Setup
Use this procedure to set up the spray system.
1. Make sure the diaphragm pump ON/OFF switch and the
compressor ON/OFF switch are in the OFF position.
2. Make sure the pressure control knob is turned fully
counterclockwise to its lowest pressure setting.
3. Using a wrench, attach a minimum of 7.5 m of 6 mm nylon
airless spray hose to the material outlet tting on the pump.
Tighten securely.
4. Attach the air hose to the air outlet tting on the compressor.
Tighten securely.
5. Lockthegunbyippingthetriggerlockintolockposition(see
spraygunmanual).
Make sure to read the spray gun’s instruction
manual in order to be familiar with all of its functions
and corresponding safety information.
6. Attach the spray hose to the material inlet tting on the spray
gun.Usingtwowrenches(oneonthegunandoneonthe
hose),tightensecurely.
Make sure all airless hoses and spray guns are
electrically grounded and rated for at least 193 bar
(19 MPa, 2800 PSI) uid pressure.
7. Attach the air hose coupling to the air inlet tting on the spray
gun. Attach the air hose to the coupling. Tighten securely.
Reversing the hose connections could result in
serious injury. Make sure the airless spray hose is
connected from the diaphragm pump to the material
inlet tting on the gun and the air hose is connected
from the compressor to the air inlet tting on the
gun.
8. Make sure the electrical service is 10 amp minimum.
9. Plug the power cord into a properly grounded outlet at least
7.5 m from the spray area.