. Turn the pressure control knob counterclockwise to the
m
inimum setting.
10. Place the attached suction tube and return hose into the
container of water or appropriate solvent.
11. Remove the spray tip and guard and place them into a
container of the appropriate solvent.
12. Increase the pressure to 1/2 the maximum pressure. Let
the water or solvent circulate for 2-3 minutes to flush paint
out of the pump, the suction tube and the return hose.
Clearing the Paint Hose
1. To save material left in the hose, release the gun trigger
lock and carefully trigger the gun with the spray tip
removed against the inside of the material container.
2. Turn the pressure control knob counterclockwise to the
minimum pressure setting.
3. Turn the PRIME/SPRAY valve to SPRAY.
4. Turn the pressure control knob slowly until material starts
to flow into the bucket. As soon as the water or solvent
starts to come into the bucket, release the trigger.
5. Change to clean water or solvent, point the gun to the
side of the waste bucket, and continue circulating for
another 5 minutes to thoroughly clean the hose, pump
and spray gun.
6. Turn the pressure control knob counterclockwise to its
lowest setting.
7. Turn the PRIME/SPRAY valve to PRIME.
8. Trigger the gun to remove any pressure which may still be
in the hose.
9. Lock the gun trigger by rotating the trigger lock forward
until it stops.
10. Move the motor ON/OFF switch to OFF.
11. Cover the material container and set it aside.
Clearing the Gun
1. Remove the spray gun from the paint hose using two
adjustable wrenches.
2. Remove the filter housing from the gun. Place the gun
and the filter assembly into a container of water or solvent
to soak.
3. Clean the spray tip and gun filter with a soft brush.
4. Reassemble the gun and filter. Assemble the spray tip in
the cleaning position with the arrow pointing to the back of
the gun.
5. Attach the paint hose to the gun and tighten using two
wrenches.
6. Move the motor ON/OFF switch to ON.
7
. Unlock gun trigger by turning the gun trigger lock so that it
i
s parallel to the gun handle.
8. Turn the PRIME/SPRAY valve to SPRAY and point the
gun to the side of the waste bucket.
9 Trigger the gun and gradually turn the pressure control
knob clockwise to 1/2 pressure. Continue to trigger the
gun for approximately 30 seconds.
1
0. Turn the pressure control knob counterclockwise to its
lowest setting.
11. Turn the PRIME/SPRAY valve to PRIME.
12. Trigger the gun to remove any pressure which may still be
in the hose.
13. Lock the gun trigger by rotating the trigger lock forward
until it stops.
14. Move the motor ON/OFF switch to OFF.
Final Cleanup
1. Remove the tip assembly.
2. Move the motor to ON.
3. Turn the PRIME/SPRAY valve to SPRAY.
4. Turn the pressure control knob clockwise to 1/2 power.
5. Trigger the gun into the cleaning bucket until the hopper
or solvent bucket is empty.
6. Refill the hopper or solvent bucket and continue flushing
the system until the solution coming out of the gun
appears clean.
7. Lock the gun and turn the pressure control knob
counterclockwise to its lowest setting.
8. Turn the PRIME/SPRAY valve to PRIME.
9. Remove the hopper or suction set from the inlet valve.
10. Clean the threads of the inlet valve with a damp cloth.
11. Fill the inlet valve with a light
household oil.
12. Turn the PRIME/SPRAY valve to
SPRAY to distribute the oil.
13.
T
urn the pressure control knob
counterclockwise to its lowest setting.
14. Turn the PRIME/SPRAY valve to PRIME.
15. Trigger the gun to remove any pressure that may still be in
the hose.
16. Lock the gun trigger by rotating the trigger lock forward
until it stops.
17. Move the motor ON/OFF switch to OFF.
18.
Remove the hopper filter and clean in clean water or the
appropriate solvent. Use a soft brush.
19. Return the hopper filter to its position in the hopper.
20.
Replace the hopper or suction set on the inlet valve.
21. Wipe the entire unit, hose, and gun with a damp cloth to
remove accumulated material.