Wagner SprayTech Finish 250 Paint Sprayer User Manual


 
14
Finish 370 / 250
GB
8.1 CLEANING THE UNIT FROM THE OUTSIDE
First unplug the power plug from the outlet.
Danger of short-circuits caused by water
ingression! Never spray down the unit with
high-pressure or high-pressure steam clea-
ners.
Wipe down unit externally with a cloth which has been im-
mersed in a suitable cleaning agent.
8.2 SUCTION FILTER
Clean  lters always ensure maximum volume,
constant spray pressure and problem-free
functioning of the unit.
Unit with suction system
1. Unscrew the  lter (Item 1) from the suction tube.
2. Clean or replace the  lter.
Carry out cleaning with a hard brush and a corresponding
cleaning agent.
8.3 HIGHPRESSURE FILTER
1. Open relief valve
valve position (circulation) - Switch the unit o .
2. Open the high-pressure  lter and clean the  lter insert. To
do so:
3. Unscrew the  lter housing (1) by hand.
4. Remove the  lter insert (2) and pull out the bearing spring
(3).
5. Clean all the parts with the corresponding cleaning agent.
If compressed air is available – blow through the  lter in-
sert and bearing spring.
6. When mounting the  lter ensure that the bearing ring (4)
in the  lter insert is positioned correctly and check the O-
ring at the  lter housing for damage.
7. Screw on the  lter housing by hand until it stops (a higher
tightening force only impedes later dismantling).
CLEANING THE UNIT
The container must be earthed in case of
coating materials which contain solvents.
Caution! Do not pump or spray in container
with small opening (bunghole)!
See safty regulations.
5. Fill up hopper with suitable cleaning agent.
6. Open relief valve
valve position (circulation)
7. Pump suitable cleaning agent in the circuit for several mi-
nutes.
with cleaning ring (TopClean) step 8 up to 12
8. Switch reverser knob into a horizontal position.
The cleaning agent will  ow around the circumference of
the inner hopper wall and will clean it in some minutes,
depending of the fouling
9. Switch reverser knob into the upright position.
Cleaning agent is  owing directly into the hopper
Do not switch the reverser knob at the clea-
ning ring into the horizontal position when
the pump is load with coating material. The
devider holes can be plugged.
Than the cleaning work of cleaning ring is
reduced, and it will take more time up to the
cleaning ring has cleaned themself.
10. Close relief valve,
valve position (spraying)
11. Pump the remaining cleaning agent from the hopper,
high-pressure hose and the spray gun into an open con-
tainer
12. Open relief valve
valve position (circulation)
13. Switch o unit
1
2
suction tube 5l hopper
Unit with hopper
1. Release screws with a screwdriver (Item 2).
2. Lift and remove  lter disk with a screwdriver
3. Clean or replace the  lter disk.
Carry out cleaning with a hard brush and a corresponding
cleaning agent.