Feature
Switch
Number
Set Point
Equalize or
3 Stage
Charging
1
Toggle
On/Off
Equalize (Do not leave on.)
Off 3 Stage Charging*
Battery
Type
2 3
On On Warm Gel Cell (>80 deg. F.)
Off On Cool Gel Cell (<80 deg. F.)
On Off Warm Wet Cell (>80 deg. F.)
Off Off Cool Wet Cell (<80 deg. F.)*
Auto
Charge
4
On
Disable: Charger responds to On/Off
switch.
Off
Enable: Charger on when AC
connected.*
5 6
Not used.
Power
Sharing
7 8
On On 2.5 Amps
Off On 5 Amps
On Off 10 Amps
Off Off 15 Amps*
DIP SWITCH PROGRAMMING
1000 2500
*indicates factory default setting.
5 Amps
5 Amps
15 Amps
20 Amps
20 Amps
30 Amps
2000
11
30 Amps*
Disabled*