975-0390-01-01 35
Warning Messages
For error codes to :
• the unit will stop inverting, and
• the display screen and the alarm will turn off after 30 seconds.
For error codes and :
• the unit will stop charging, but
• the error code will still show on the display screen and the alarm will
remain on, and
• AC power will continue to pass through to the AC outlets.
For error code
• the unit will stop charging and shut down, and
• the error code will show on the display screen briefly, and
• AC power will not pass through to the AC outlets.
To reset error codes to :
1. Remove the AC input, and
2. Turn the unit OFF and then turn ON again using the Inverter Power
button on the display panel.
Battery is bad or external DC
load is connected to the battery.
AC shore power • Check the battery bank.
NOTE: The battery voltage did not rise above 5 volts DC after 1
minute or 10 volts DC after 15 minutes.
• Check that the external DC load current consumption is below the
charging current setting.
• Disconnect the DC load or increase the charger current setting.
Table 1
Error Codes Displayed on the Display Panel Screen
Error Code Condition Mode Action
Freedom HF InvChg Owners Guide.book Page 35 Thursday, November 24, 2011 11:20 AM