Xantrex Technology XC2524 Battery Charger User Manual


 
Operation
3–14 975-0187-01-01
Reporting While Battery Monitoring
The XC Series is considered to be battery monitoring if it is experiencing a charger
level fault. If there is a charger level fault (affecting all banks), all charging will be
suspended until the charger fault is resolved (see “Error Messages on Remote
Display” on page 4–4).
The remote will display all of the following, in order:
Highest level charger fault or warning (if present)
Bank 1 Highest level bank fault or warning (if present)
Bank 1 Charging Stage
Bank 1 Battery Voltage
Bank 1 Charger Current
Bank 2 Highest level bank fault or warning (if present)
Bank 2 Charging Stage
Bank 2 Battery Voltage
Bank 2 Charger Current
Bank 3 Highest level bank fault or warning (if present)
Bank 3 Charging Stage
Bank 3 Battery Voltage
Bank 3 Charger Current
Reporting While Disabled
If AC power has been disconnected or if you have used the remote display to
disable the XC Series the unit is considered to be disabled. The remote display is
also disabled at this time.
While the XC Series is disabled, you may wish to see the present status of the
banks.
To view the present status of the banks:
Press
ON/STANDBY.
If AC power is disconnected, the remote display will show one cycle (similar to the
battery monitor cycle) for each bank that was qualified as present and healthy
during the last battery detection cycle. The remote display will turn itself off after
one complete cycle.