![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/0/ac/0acf19d2-5942-4843-a150-7ad8ec9c88f9/0acf19d2-5942-4843-a150-7ad8ec9c88f9-bg67.png)
COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001
CHAPTER 2 ORIGINAL EXPOSURE SYSTEM
2-16 R
5.1 Exposure Lamp
5.1.1 Removing the Exposure Lamp
• Do not start to work if the
lamp is hot.
• Do not leave fingerprints on
the surface of the lamp.
• Do not subject the lamp to
impact.
• Do not touch the light win-
dow of the lamp without a
means of protection.
• Do not impose force on the
lamp.
• If the surface of the lamp is
soiled, dry wipe it.
1) Remove the copyboard glass. (p. 3-11R)
2) Remove the reader front cover (2
screws) and the reader rear cover (5
screws).
3) While taking care not to hold the scan-
ning lamp [1] and the reflecting shade
[2], move the No. 1 mirror base [3] as
far as the cut-off in the frame.
4) Remove the three screws [4] from the
No. 1 mirror base, and detach the scan-
ning lamp [1] together with the cable
fixing plate [5].
F02-501-01
5) Remove the screw [1], and detach the
connector cover [2] found at the rear.
F02-501-02
[1]
[4]
[2]
[4]
[1]
[5]
[3]