![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/e/75/e75bf97d-5165-41ca-9ef7-7705540ac510/e75bf97d-5165-41ca-9ef7-7705540ac510-bg4.png)
MG500-EU-EN v1.0 7/13
4
Features
InsulationResistanceTesting
Thisdigitalinsulationresistancetesterwillmeasureinsulationresistancefrom800kohmsto
500GohmsusingDynamicAuto‐ranging technology.Testvoltagesrangefrom500Vto10kV
in500Voltsteps.ThisinstrumentalsoemploysanAuto‐Dischargeutility.
DAR:DielectricAbsorptionRatioTesting
The
DielectricAbsorptionistheratiooftheInsulationResistance,measuredat60seconds,
dividedbytheInsulationResistancemeasuredat30seconds).
DAR=Resistancemeasuredat1minute/Resistancemeasuredat30seconds
PI:PolarizationIndexTesting
ThePolarizationIndexistheratiooftheInsulationResistancemeasured
at10minutes
dividedbytheInsulationResistancemeasuredat1minute.
PI=Resistancemeasuredat10minutes/Resistancemeasuredat1minute
AutomaticDischargeofCapacitiveandInductiveCircuits
Thisinstrumentwillautomaticallydischargeallcircuits,chargedbythetester,upon
completionofatest.The
dischargecanbeobservedontheinstrument’sbargraphdisplay.
AutomaticBatteryTest
WhentheinstrumentisfirstpoweredON,atestcircuitappliesaheavycurrentdrawonthe
batteriesforafewsecondsandmeasuresthevoltageinordertodeterminethecapacityof
thebatteries.Theresultis
shownonthedisplay.
NormalOperationModeConsiderations
ThisinstrumentusesDynamicCurrentAuto‐rangingtechnology.Thebargraphwill
displaythevoltagethatisstressingtheinsulationduringthefirst30secondsofatestand
duringthedischargeofthecircuitsattheendofthetest.Thedisplaywillalsoshowthe
elapsedtimefromthestartofthetestandthetotaltime,evenafterthetestinghasstopped.
SupplementalFeatures
o InsulationResistanceauto‐rangingonallVoltageranges
o AutomaticDARcalculation
o AutomaticPIcalculation
o Ener‐Save™Modeconservesbattery
energyduringInsulationResistancetesting
o Overloadprotection
o Lowbatteryindicator
o AutoOfffeature
o Warningofexternalvoltagepresence(>500VACorVDC)