Reference Station GPS1200 71
Behaviour when
turning off and on
Turning the GRX1200 Series off and on again resets the receiver. The conse-
quences are:
If the configuration of the output is stored in the configuration set, standard
NMEA messages are still output.
All data/message outputs scheduled via OWI or LB 2 commands are no longer
output.
Data logging parameters and interface configuration options, that have been set
by OWI or LB 2 commands and have not been saved to a configuration set using
the corresponding OWI or LB 2 command, are reset.
Behaviour after
power failure
After temporary power failure, the GRX1200 Series will automatically power itself up
and resume the previously set operations. Two power fail recovery options are avail-
able - Sudden Loss Only and Always. To access the configuration select Main
Menu: Config...\General Settings...\Start Up & Power Down.