A SERVICE OF

logo

31
z Turn the long drive shaft 45 clockwise until the line marks on edge 34 of feeding eccentric and
connection rod 10 are opposite each other (fig. 19).
Cross-check:
z Turn the handwheel back and forth, until until the needle-rise clamp rests on the spacer.
The line marks must now be opposite each other.
z Tighten all three screws 44 very firmly.