7. Install a new abrasive belt by sliding the abrasive
over the tension roller and contact wheel. See
figure #8.
8. Rotate the release lever upward and back to
tighten the abrasive belt.
9. Make sure the motor circuit breaker is in the "Off"
position. Plug the pigtailed power cord into the
handle. Twist the cord connection clockwise to
lock.
10. Jog (turn on momentarily) the motor circuit
breaker while observing the belt tracking. Follow
the procedures outlined in the "Sander Adjust-
ment Procedures" on page 13 to correct the belt
tracking. There is also a label on the inside of
the access door that outlines the belt adjust-
ment.
11. Close the access door. Place the end of the
draw latch over the keeper on the access door
and push the draw latch flat against the main-
frame to secure.
Figure 8