- 12 -
Program Mode
Entering Program Mode:
Program Mode is used to change any or all of the Operation Features. To enter Program
Mode depress the push-button until the yellow and green LED's begin toggling (30 sec.), then
release. The LED's will then output the current set-up configuration (and every 3 sec.
thereafter). For example: an output of yellow, yellow, yellow tells you that the current
configuration is Level Shift, Light Operate, and Normal Contrast Setting.
Table of Features:
Changing a Feature:
To change a feature, depress the push-button the corresponding number of times. This
will change the current feature from A to B, or from B to A. For example: If you wanted to
change the output from Level Shift to Pulse, you would depress the push-button 1 time - the
LED's would then output green, yellow, yellow. Repeat this step if you want to change more than
one feature.
Exiting Program Mode:
To exit Program Mode depress the push-button until the yellow and green LED's begin
toggling (2 sec.), then release. This puts you back in the standard operating mode.
OUTPUT MODE
LIGHT/DARK OPERATION
CONTRAST SETTING
*A. Level Shift - (default factory setting)
*A. Output on Web - Light - (default factory setting)
*A. Normal Contrast Setting - (default factory setting)
B. Low Contrast Setting
B. Output on Label - Dark
B Pulse
1
2
3
Level Shift Output
Level Shift Output
Pulse Output
Pulse Output
WEB
LABEL
WEB
WEB
WEB
LABEL
LABEL
LABEL LABEL
LABEL
ON
ON ON
ON
ON
2 m.s.
2 m.s.
OFF
OFF
OFF
OFF OFF
Yellow LED
Green LED
Green LED
Green LED
Yellow LED
Yellow LED