Contec CS2000-QD Stud Sensor User Manual


 
- 7 -
Installation
CS2000-QD Wiring:
The CS2000-QD comes with a 6" quick disconnect M12 - 4 pin male cable/connector (Turck
P/N RS4.4T-2). Refer below for wire designations.
Pin 1. BRN = 10-30 VDC
Pin 2. WHT = Output
Pin 3. BLU = Common
Pin 4. BLK = NPN / PNP Output Selector
Optoisolator
CS2000-QD
BRN
10-30V
LOAD
BLU
WHT
BLK
WHT
BLK
WHT
BLK
WHT
BLK
WHT
+5V
5V Logic
1K
1/4W
Supply
Voltage
12V = 1K 1/4W
24V = 2K 1/4W
12V = 1K 1/4W
24V = 2K 1/4W
Optoisolator
*5V Com. and 10-30V Com.
must be connected together
*Output Source Com. and Supply
Com. must be connected together
*Resistor values are to source approx.
10mA to the optoisolator
*Resistor values are to source approx.
10mA to the optoisolator
BLK
WHT
BLK
CS2000-QD
CS2000-QD
CS2000-QD
CS2000-QD
CS2000-QD
Interfacing to Load - NPN Output:
Interfacing to 5V Logic - NPN Output:
Sourcing Other than Supply Voltage - PNP Output:
Interfacing to Optoisolator - PNP Output:Interfacing to Optoisolator - NPN Output:
Interfacing to Load - PNP Output:
LOAD
LOAD
BRN
10-30V
BRN
BRN
10-30V
BLU
BLU
10-30V
BLU
BRN
10-30V
BLU
BRN
BLU
10-30V
Output
Source
Voltage
10-30V
4
1
2
3