Contec CS2000-QD Stud Sensor User Manual


 
- 3 -
General Information
CS2000 Quick Start:
1.  Connect red wire to supply voltage
2.  Connect black wire to supply common
3.  For NPN Output - connect orange wire to black wire
For PNP Output - connect orange wire to red wire
4.  Connect white wire to your controller - refer to page 6 for wiring diagrams
5.  Turn on power
6.  Peel off a label and position the label backing (web) under the sensing area
7.  Depress the push-button until the yellow LED comes on (1 sec.), then release
8.  The yellow LED will begin flashing
9.  Move a label under the sensing area and the green LED will come on
10.  The label sensitivity is now adjusted and the sensor should function correctly
11.  The yellow LED indicates when label backing (web) is detected
12.  The green LED indicates when label over label backing is detected
13.  The red LED indicates when the output is active - NPN sinking or PNP sourcing