Contec CS2000-QD Stud Sensor User Manual


 
- 4 -
General Information
CS2000-QD Quick Start:
1.  Plug the CS2000-QD's male connector into a suitable 4 pin female connector
2.  Connect brown wire to supply voltage
3.  Connect blue wire to supply common
4.  For NPN Output - connect black wire to blue wire
For PNP Output - connect black wire to brown wire
5.  Connect white wire to your controller - refer to page 7 for wiring diagrams
6.  Turn on power
7.  Peel off a label and position the label backing (web) under the sensing area
8.  Depress the push-button until the yellow LED comes on (1 sec.), then release
9.  The yellow LED will begin flashing
10.  Move a label under the sensing area and the green LED will come on
11.  The label sensitivity is now adjusted and the sensor should function correctly
12.  The yellow LED indicates when label backing (web) is detected
13.  The green LED indicates when label over label backing is detected
14.  The red LED indicates when the output is active - NPN sinking or PNP sourcing