Craftsman 152.213371 Dust Collector User Manual


 
Turnthepowerswitch"OFF"andunplugthepower
cordfromitspowersourcepriortoanymaintenance,
Alwaysmakesurethattheintakeportcapscoversthe
intakeportwhena hoseis notconnectedtothedust
collector.
TheDustCollectorhassealedlubricatedbearingsin
themotorhousingthatdoesnotrequireanyadditional
lubricationfromtheoperator,
WiththeDustCollectorunplugged,blowoffmotorwith
lowpressureairto removedustordirt,Airpressure
above50 R S.I.shouldnotbe usedashigh-pressured
airmaydamageinsulation.Theoperatorshouldalways
weareyeprotectionwhenusingcompressedair.
Donotallowchipsanddusttoaccumulateunderdust
collector.Keepareacleanandinsafeorder.
CAUTION:DONOTUSEFLAMMABLEMATERIALS
tocleanDustCollector.
Repairsto theDustCollectorshouldbeperformedby
trainedpersonnelonly.ContactyournearestSears
ServiceCenterforauthorizedservice.Unauthorized
repairsor replacementwithnon-factorypartscould
causeseriousinjurytotheoperatoranddamageto the
DustCollector.
TOPREVENTINJURYTOYOURSELFordamageto theDustCollector,turntheswitchto the"OFF"positionand
unplugthepowercordfromtheelectricalreceptaclebeforemakinganyadjustments,
PROBLEM
Motor does
not start
Motor stalls
(resulting in blown
fuses or tripped
circuit breakers)
Motor starts
slowly or falls to
come to full speed
Motor running
too hot
Frequent opening
of fuse or circuit
breakers
LIKELY CAUSE(S) SOLUTION
1. Switch not pressed in tar enough or
switch in the "OFF" position
2. Detective switch
3. Detective capacitor
4. Low line voltage
5. Detective motor
1.
2.
3.
4.
5.
6.
1.
2.
1. Depress switch in 1/2 inch or make sure switch
is in the "ON" position.
2. Have switch replaced.
3. Have capacitor replaced.
4. Correct low line voltage condition.
5. Have motor replaced/repaired.
NOTE: 2, 3 and 4 must be done by a qualitied service
technician; Contact Sears service.
Circuit overload 1.
Low line voltage 2.
Chips or debris clogged impeller. 3.
Motor ovedoad 4.
incorrect tuses on circuit breakers 5.
Short circuit in motor; loose connections 6.
or worn insulation on lead wires
Detective motor windings 1.
Detective capacitor
1. Restricted air circulation due to dust
accumulation.
2. Motor overload
1. Fuses or circuit breakers do not have
sufficient capacity
2. Circuit overloaded
3. Motor overload
Reduce circuit load
Correct low line voltage condition.
Clean all hoses, bags and blower housing of chips
and debris.
Reduce load on motor.
Have correct tuses on circuit breakers installed.
inspect terminals in motor for damaged insulation
and shorted wires and have them replaced.
Have motor replaced/repaired.
2. Have capacitor replaced.
1A, Clean dust and restore normal air circulation.
1B. Empty and clean tilter and collection bags.
2. Reduce load on motor.
1. Have correct tuses or circuit breakers installed.
2. Reduce circuit load (turn off other appliances).
3. Reduce load on motor.
2O