6
UNPACKING AND CLEANING
Carefully unpack the drill press and all loose items from the carton. Remove the protective coating from the
machined surfaces of the drill press and all loose items. This coating may be removed with a soft cloth moist-
ened with kerosene. DO NOT USE ACETONE, GASOLINE, OR LACQUER THINNER FOR THIS PURPOSE.
Fig. 2
Fig. 3
ASSEMBLING THE
DRILL PRESS
1. Assemble column (A) Fig. 2, to base (B) using four
M-12 x 45mm long hex head screws (three of which are
shown at [C]). Loosen set screw in collar (D) and remove
collar (D) and raising rack (E).
2. Remove bolt (F) Fig. 3, and remove table (G) from
table bracket (H).
H
G
F
B
C
A
E
D