Emerson VSG Air Compressor User Manual


 
3 – 19
VSG/VSSG • Installation, Operation and Maintenance Manual •Vilter/Emerson • 35391SSG
OIL
PT
004
FG
001
TE
001
PT
001
BLEED
BLEED
DRAIN
PT
002
BLEED
TE
004
QE
101
QE
102
QE
103
TE
005
1000W 1000W 1000W
LG
001
LG
002
OIL CHARGE
TE
002
COMPRESSOR
MOTOR
OIL COOLER
MOTOR
OIL PUMP
OIL FILTER
OIL FILTER
COALESCING OIL RETURN LINE
PRESSURE
EQUALIZING LINE
SUCTION INLET
DISCHARGE OUTLET
OIL MIXING
VALVE
DRAIN
OPEN
OPEN
OPEN
CLOSE
OIL SEPARATOR
DRAIN
DRAINVENT
COOLING
WATER
DISCHARGE OUTLET
SUPPLY
RETURN
Figure 3-18. Priming Compressor (with Shell & Tube Oil Cooler) and Piping
Section 3 • Installation
NOTE
Oil separator does not need to be lled again until oil
level reaches Minimum Operating Level.
Every size of compressor will hold different amounts
of oil, so amount of oil draining back into oil
separator will vary.
21. More accurate ll levels can be accomplished by
marking the level on the oil separator (2) after cor-
rect levels have been achieved during the unit oper-
ation and when the compressor unit has been down
for 1 hour.
3
8
8
7
6
5
1
2
4
9