Graco 24R021 Glue Gun User Manual


 
Operation
8 332198C
Operation
Prime
Perform this procedure whenever air is introduced into
the material lines, such as after connecting the material
supply lines to the dispense valve.
1. Perform Pressure Relief Procedure on page 10.
2. If a static mixer is installed, remove static mixer.
3. Use lever (H) to open the dispense valve inlet ball
valves (J).
4. If necessary, prime the proportioner. See propor-
tioner manual for priming instructions.
5. Run the proportioner until clean, air-free material
begins to exit the dispense valve.
6. If necessary, Pressure Balance the Gun.
7. Install Disposable Static Mixer.
Pressure Balance the Gun
Balancing the back pressure:
controls ratio lead-lag when the gun opens
holds pressure in the hose, providing a very smooth
flow
minimizes oozing from mixer
minimizes material crossover.
1. Use lever (H) to close the dispense valve inlet ball
valves (J).
2. Remove static mixer.
3. With the static mixer removed, dispense into a
waste container. Note pressure gauge readings. If
pressures are more than 25% apart, continue to
next step. If not, pressures are sufficiently balanced.
4. If pressures are more than 25% apart, replace one
or both plugs or restrictors with a different restrictor
size:
NOTE: An extra 0.032 in. restrictor is included with the
gun. If necessary, use this restrictor to balance the pres-
sures. Put the larger orifice on the side with the higher
viscosity material.
a. Perform Pressure Relief Procedure on
page 10.
b. Select the new restrictors required to achieve
desired back pressure and balance. See pres-
sure drop chart in F
IG. 2 on page 15.
NOTE: The valve should be able to achieve the desired
flow rate at a pressure of 200-1500 psi (1.4-10 MPa,
14-103 bar). A (ISO) and B (RES) pressures should bal-
ance within 25% of each other.
c. Install Restrictors or Plugs, see page 11.
d. Repeat this procedure to verify pressures are
balanced.
NOTICE
Always open and close lever (H) fully and quickly.
Opening the valve partially or slowly will cause soft
spots in the material and may shut down the propor-
tioner because of a pressure imbalance.
NOTICE
Always open and close lever (H) fully and quickly.
Opening the valve partially or slowly will cause soft
spots in the material and may shut down the propor-
tioner because of a pressure imbalance.