Isocyanate Hazard
10 309550U
Isocyanate Hazard
Keep A and B
Components
Separate
Grounding
Check your local electrical code and proportioner man-
ual for detailed grounding instructions.
Ground the spray gun through connection to a
Graco-approved grounded fluid supply hose.
Piston Safety Lock
Engage piston safety lock whenever you stop spray-
ing, to avoid accidental triggering.
WARNING
Read Material Safety Data Sheet (MSDS) to know the
specific hazards of isocyanates. Use equipment in a
well-ventilated area. Wear respirator, gloves, and pro-
tective clothing when using isocyanates.
CAUTION
To prevent cross-contamination of the gun’s wetted
parts, do not interchange A component (isocyanate)
and B component (resin) parts. The gun is shipped
with the A side on the left. The fluid manifold, fluid
housing, side seal cartridge, check valve cartridge,
and mix chamber are marked on the A side.
WARNING
Read warnings, page 8.
WARNING
Read warnings, page 7.
To engage piston safety lock: push knob in and turn
clockwise. If engaged, gun will not actuate.
To disengage piston safety lock: push knob in and
turn counterclockwise until it pops out. There will be a
gap between knob and gun body.
TI2409A
Engaged
TI2410A