Graco 3A0149E Paint Sprayer User Manual


 
Operation
12 3A0149E
HVLP Operation
NOTE: For HVLP operation, the atomization air must not
exceed 10 psi. Use HVLP Verification Kit 24C788 to ver-
ify air psi.
NOTE: There is no fan adjustment when using RAC tips
and caps.
Fluid Application
Always hold the gun at a right angle from the surface.
Do not make an arc with the gun as it causes an uneven
coat of fluid. See F
IG. 15.
1. To achieve the best results when applying fluid,
keep the gun perpendicular to the surface and main-
tain a consistent distance of approximately 8 to 12
in. (200 to 300 mm) from the object being sprayed.
2. To obtain an even finish, use smooth, even strokes
across the object being sprayed with 50% overlap.
3. Paint using parallel strokes. This spray gun applies
all coatings evenly without cross coating.
F
IG. 15
TI6561A
TI6562A
INCORRECT