Graco 3A0149E Paint Sprayer User Manual


 
Spray Tip Selection Chart
34 3A0149E
RAC SwitchTips, for use with G40 RAC Air Cap, Continued
NOTE: All tips in the Spray Tip Selection Charts below
can be used with Model G40 guns equipped with RAC
air cap 24C921.
FFT Fine Finish RAC Spray Tips
Order desired tip, Part No. FFTxxx, where xxx = 3-digit number from matrix below.
WRX WideRAC Spray Tips
Order desired tip, Part No. WRxxxx, where xxxx = 4-digit number from matrix below.
* Tips are tested in water.
Measured with NO airflow. Air assist will tend to reduce pattern lengths by 1 in. to 2 in.
Orifice Size in.
(mm)
* Fluid Output at
2000 psi (14.0 MPa, 140 bar)
fl oz/min (lpm)
Maximum Pattern Width at 12 in. (305 mm)
in. (mm)
4 to 6
(150)
6 to 8
(200)
8 to 10
(250)
10 to 12
(300)
12 to 14
(350)
Spray Tip
0.008 (0.203) 8.8 (0.26) 208 308
0.010 (0.254) 13.9 (0.41) 210 310 410 510
0.012 (0.305) 19.9 (0.59) 212 312 412 512 612
0.014 (0.356) 27.0 (0.80) 214 314 414 514 614
Orifice Size
in. (mm)
* Fluid Output at
2000 psi (14.0 MPa, 140 bar)
fl oz/min (lpm)
Maximum Pattern Width at 12 in. (305 mm)
24 in. (610 mm)
Spray Tip
0.021 (0.533) 60.5 (1.79) 1221
0.023 (0.584) 72.7 (2.15) 1223
0.025 (0.635) 85.9 (2.54) 1225
0.027 (0.686) 100.0 (2.96) 1227
0.029 (0.737) 115.6 (3.42) 1229
0.031 (0.787) 131.8 (3.90) 1231
0.033 (0.838) 149.4 (4.42) 1233
0.035 (0.889) 168.3 (4.98) 1235
0.037 (0.940) 187.9 (5.56) 1237
0.039 (0.991) 208.9 (6.18) 1239
Fluid output (Q) at other pressures (P) can be calculated by this formula: Q = (0.041) (QT)
where QT = fluid output (fl oz/min) from the above table for the selected orifice size.
P