Graco Inc. 2004230905 Paint Sprayer User Manual


 
Optional Configurations
309856P 19
Optional Configurations
Optional Fluid Manifold
Position
Fluid manifold is mounted to bottom of gun, with A side
on left, viewed from operator’s position at back of gun. If
desired, manifold may be moved to top of gun. Doing
this will reposition A side parts (fluid inlet, check valve,
and fluid housing A side) to right.
CAUTION
To prevent cross-contamination of gun’s wetted parts,
do not interchange A component (isocyanate) and B
component (resin) parts.
1. Follow Pressure Relief Procedure, page 18.
2. Disconnect air (D) and remove fluid manifold (G).
TI3837a
G
P
F
D
3. Unscrew lock ring (P) until front end of gun is
loose.
4. Rotate fluid housing (F) 180° and retighten lock
ring very securely.
5. Attach fluid manifold. Connect air. Return gun to
service.