Maintenance
26 309856P
Clean CeramTip
Round CeramTip Flat CeramTip
External Quick Cleaning Method
1. Follow Pressure Relief Procedure, page 18.
2. Remove CeramTip, page 34.
3. Clean CeramTip hole with appropriate size drill
(supplied). See T
ABLE 2. Also see identification
chart under Drill Bit Kits, page 51.
Table 2: Cleanout Drill Sizes for Round CeramTips
Round CeramTip Kit
Part No.
Drill Size
(nominal)
Cleanout Drill Diameter
in. (mm)
RTM024 #73 .0240 (0.61)
RTM030 #67 .0320 (0.81)
RTM040 #60 .0400 (1.02)
RTM055 #54 .0550 (1.40)
RTM070 #50 .0700 (1.78)
RTM080 2.0 mm .0787 (2.00)
RTM090 #43 .0890 (2.26)
RTM100 #39 .0995 (2.53)
RTM110 7/64 0.1094 (2.78)
4. Clean CeramTip internal dome with 15D234 Tip
Cleanout Tool, page 53.
TI3868a
1. Follow Pressure Relief Procedure, page 18.
2. Remove CeramTip, page 34.
3. Soak CeramTip in compatible solvent. Clean gen-
tly with 15D234 Tip Cleanout Tool, page 53, to fit
tip configuration.
4. Reposition CeramTip horizontally or vertically.
1. Engage piston safety lock, page 12.
2. Close fluid valves A and B.
TI3867a
TI3850a
TI2411A