Graco Inc. EFX Paint Sprayer User Manual


 
Setup
313869B 15
Connect Fluid Hose
NOTE:
Before connecting the fluid line, blow it
out with air and flush it with solvent. Use
solvent that is compatible with the fluid
to be sprayed.
Install a fluid regulator (L) on the fluid
line to control fluid pressure to the gun.
See FIG. 8.
Install a fluid shutoff valve (M) to shut off
the fluid supply to the gun.
Filter the fluid line of coarse particles
and sediment to avoid clogging the fluid
nozzle and causing finishing defects.
Inline fluid filter 24B707 is available.
1. Connect the fluid supply hose (J) to the gun
fluid inlet (S), 6 mm OD tube fitting. See
F
IG. 9.
2. Connect the other end of the fluid hose (J)
to a regulated fluid supply outlet (M).
3. In a circulating system, connect a
grounded fluid return hose to the gun fluid
outlet (T). See FIG. 9.
In a non-circulating system, remove the
gun fluid outlet fitting (T) and plug the outlet
port with the pipe plug (33) supplied for
guns without manifold. Guns with manifold
use plug 24C211 (25, see page 10).
FIG. 8: Connect Fluid Hose.
M
L
K
J
ti7016a
FIG. 9: Air and Fluid Ports
KEY
N Cylinder Air Inlet: accepts 6 mm OD tubing
P Atomization Air Inlet: 6 mm OD tubing
R Fan Air Inlet: 6 mm OD tubing
S Fluid Inlet: 6 mm OD tubing
T Fluid Outlet (circulating gun only): 6 mm OD tubing
N
S (or T)
T (or S)
P
R
N
S (or T)T (or S)
RP
Without Manifold
With Manifold
TI14437A
TI14436A