Model G0440/G0441 (Mfg. Since 03/12)
b. Connect the gray flexible hose from
the outlet port to the canister adapter
and secure it in place with the two 7"
hose clamps, as shown in Figure 21.
Model G0441:
a. Apply the 3 x 15mm foam tape to
the lips of the outlet port, canister
adapter, and both ends of the muf-
fler, as shown in Figure 22.
Figure 22. Foam tape applied to upper
components (Model G0441).
Foam
Tape
Foam
Tape
b. Attach the 8" x 5" gray flexible hose
between the canister adapter and
the muffler with two 8" hose clamps,
then attach the 8" x 20" gray flexible
hose between the muffler and the
outlet port with the remaining two 8"
hose clamps (see Figure 23).
Note: It may be necessary to reposition the
canister L-braces down one bolt hole or
shorten the length of the longer piece of flex-
ible hose to accommodate the bend in the
hose.
Figure 23. Muffler properly positioned between
the two gray flexible hoses (Model G0441).
Muffler
14. Attach the casters to the bottom of the lower
collection drum, as shown in Figure 24, using
the (4)
3
8"-16 hex nuts, (8)
3
8" flat washers,
and (4)
3
8" lock washers included in the box
with the casters.
Figure 24. Casters attached to the lower
collection drum.
Figure 21. Gray hose properly installed (Model
G0440).
Hose
Clamps