Grizzly G4186Z Saw User Manual


 
G4186Z 18" Bandsaw -5-
220V Operation
The motor supplied with the Model G4186Z
comes prewired for 220V. Refer to the wiring dia-
gram supplied at the back of this manual for more
specific information about wiring connections.
Under normal use, the motor draws approximate-
ly 12 amps at 220V. We recommend a 15 amp
circuit breaker for 220V operation. This should be
satisfactory for normal use while providing
enough protection for the circuits. Also, be sure
the wires in your circuit are rated for 15 amp ser-
vice.
This machine does not come supplied with a
plug, therefore a suitable 220V plug must be
wired in. When operating at 220V, we recom-
mend using a NEMA-style L6-15 plug and outlet.
See Figure 1A. You may also “hard-wire” the
machine directly to your panel, provided you
place a disconnect switch near the machine.
Check the electrical codes in your area for
specifics on wiring requirements.
SECTION 2: CIRCUIT REQUIREMENTS
Figure 1A. Typical 220V 3-prong plug and outlet.
110V Operation
The G4186Z Bandsaw motor can be wired to
operate at 110V. See Figure 1B. Under normal
110V use, the motor draws approximately 24
amps. We recommend a 30 amp circuit breaker,
including wires in the circuit rated to handle 30
amps.
We also recommend that the circuit you use
should be dedicated, (i.e., the G4186Z should
provide the only draw from that circuit). If frequent
circuit failures occur when using the bandsaw,
contact our Service Department or your local
electrical contractor.
Figure 1B. Typical 110V 3-prong plug and outlet.