-10-
G9743 7" x 12" Metal-Cutting Bandsaw
Serious personal injury could occur if you
connect the machine to the power source
before you have completed the set up pro
-
cess. DO NOT connect the machine to the
power source until instructed to do so.
110/220V Operation
SECTION 2: CIRCUIT REQUIREMENTS
Amperage Draw
The Model G9743 features 110/220V motor that is
prewired for 110V and draws the following amps
under maximum load:
Motor Draw at 110V ............................... 23 Amps
Motor Draw at 220V ........................... 11.5 Amps
Circuit Requirements
We recommend connecting this machine to a
dedicated circuit with a verified ground, using the
circuit breaker size given below. Never replace a
circuit breaker with one of higher amperage with
-
out consulting a qualified electrician to
ensure
compliance with wiring codes
. If you are unsure
about the wiring codes in your area or you
plan to connect your machine to a shared cir
-
cuit, you may create a fire hazard—consult a
qualified electrician to reduce this risk.
110V Circuit Breaker .............................
25 Amps
220V Circuit Breaker .............................
15 Amps
Figure 2. 6-15 plug and outlet.
Plug Type
The Model G9743 comes prewired with a NEMA
5-15 plug. If you wish to rewire the motor to 220V
you will need the following 220V plug (see Figure
2 for an example):
220V Plug & Receptacle .............................. 6-15
The Model G9743 can be rewired to operate on a
220V power source. The motor must be rewired
according to the wiring diagram on the motor
label. The wiring configuration can also be found
on the inside of the motor wire cover, as well as
on Page 39.
Wiring for 220V